Brother MFC-9840CDW All in One Printer User Manual


 
Confidential
App. 1-8
< WSW04 >
Selector No. Function Setting and Specifications
1
Earth function in transfer facility
(Not used.)
0: Provided 1: Not provided
2
3
Dual tone detection frequency
in ICM recording
No. 2 3
0 0: 350 and 440 Hz
0 1: 440 and 480 Hz
1 0: 480 and 620 Hz
1 1: 480 and 620 Hz
(A)
(B)
(C)
(C)
4
Dual tone detection sensitivity
in ICM recording
0: Normal 1: High
5
Length of time added to time
designated by selectors 3 and 4
on the WSW 24 (time between
CML ON and pseudo ring
backtone return).
0: Not added 1: +4 seconds added
6
|
8
Break time length for flash
function
No. 6 7 8
0 0 0: 80 ms
0 0 1: 100 ms
0 1 0: 110 ms
0 1 1: 120 ms
1 0 0: 200 ms
1 0 1: 250 ms
1 1 0: 500 ms
1 1 1: 700 ms
Note:
- Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is
supported.
- Selectors 2 through 4 are applicable to models equipped with built-in TADs.
- Selector 1: Earth function in transfer facility (Not used.)
This selector determines whether or not the earth function is added to the transfer setting
menu to be accessed by the function switch.
- Selectors 2 and 3: Dual tone detection frequency in ICM recording
If the machine detects either of the frequencies set by these selectors in ICM recording, it
disconnects the line. For example, if these selectors are set to “0, 0” the machine
disconnects the line upon detection of 350 Hz or 440 Hz.
- Selector 4: Dual tone detection sensitivity in ICM recording
Setting this selector to “1” increases the tone detection sensitivity in ICM recording.
- Selectors 6 and 8: Break time length for flash function
These selectors set the break time length. This setting is effective only when the flash
function is selected for the Search/Speed Dial button by using the function switch.