Confidential
3-108
(11) Remove the double-faced adhesive tape which is attached between the FFC cable ASSY
and CCD unit, and disconnect the FFC cable ASSY from the CCD unit.
Note:
- After disconnecting the flat cable(s), check that each cable is not damaged at its end or
short-circuited.
- When connecting the flat cable(s), do not insert it at an angle. After insertion, check that
the cable is not at an angle.
Fig. 3-137
(12) Push the Pulley ASSY to the direction of the arrow 12a and remove the CCD drive belt.
Fig. 3-138
CCD unit
Double-faced adhesive tape
FFC cable ASSY
Connector
CCD drive belt
Pulley ASSY
12a
12b