Brother MFC-9840CDW All in One Printer User Manual


 
Confidential
App. 1-39
< WSW34 >
Selector No. Function Setting and Specifications
1
|
3
Erasing time length of ICM tone
recorded preceding the tone
detection starting point in the
case of automatic line
disconnection due to no voice
signal received
No. 1 2 3
0 0 0: 0 sec.
0 0 1: 1 sec.
0 1 0: 2 sec.
0 1 1: 3 sec.
1 0 0: 4 sec.
1 0 1: 5 sec.
1 1 0: 6 sec.
1 1 1: 7 sec.
4
5
No. of CNG cycles to be
detected
(when the line is connected via
the external telephone in the
external TAD mode or via the
machine in F/T mode)
No. 4 5
0 0: 0.5
0 1: 1
1 0: 1.5
1 1: 2
(A)
(B)
(C)
(D)
6
7
Number of DTMF tone signals
for inhibiting the detection of
CNG during external TAD
operation
No. 6 7
0 0: 3
0 1: 2
1 0: 1
1 1: OFF
8 Not used.
Note:
Selectors 1 through 5 are applicable to models equipped with built-in TADs.
- Selectors 1 through 3: Erasing time length of ICM tone recorded preceding the tone
detection starting point in the case of automatic line
disconnection due to no voice signal received
If the machine has disconnected the line after detection of disconnection tone in ICM
recording, it erases tone recorded preceding the tone detection starting point for the time
length set by these selectors.
- Selectors 4 and 5: No. of CNG cycles to be detected (when the line is connected via the
external telephone in the external TAD mode or via the machine in
F/T mode)
The machine interprets a CNG as an effective signal if it detects a CNG signal by the
number of cycles specified by these selectors when the line is connected via the external
telephone in the external TAD mode or via the machine in F/T mode.
- Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG
during external TAD operation
If the machine receives this specified number of DTMF tone signals during external TAD
operation, it will not detect CNG afterwards.
If these selectors are set to “1, 1,” the CNG detection will not be inhibited.