Canon 5482B002 Scanner User Manual


 
CHAPTER 5 TROUBLESHOOTING
F. Ana lo g 3) Writing starts automatically and the
progress screen is displayed.
The rest of the procedure is the same as
in “For registered firmware”.
1. Analog
This mode is used to check the analog
data from sensors. Note that checking the
regular sensor operation is performed using
“Dcon Check”.
Note: This automatically detects whether the
file is for the connected scanner and
only executes writing if it is suitable. Selecting the sensor is performed from
the drop-down box. Furthermore, when a
sensor is detected, a “red circle” lights on the
left side.
Figure 5-250
Options for the drop-down box are
shown below.
Registration sensor
Door sensor
Double feed sensor
Document sensor
Separation sensor
Flapper sensor
Skew sensor
5-28
COPYRIGHT
©