Operation Panel
CL-S6621 2-56
How to change the value in the Factory Mode menu
For example, the following shows how to logically move the thermal head position 1 mm
(0.04”) toward the right side. In this case, you should add 8 (dots) to the current value (e.g.
+08).
• Variable range: -16 to +32 dots (default +00 dot) (-2 to +4 mm, -0.08 to +0.16”)
• 8 dots correspond to 1 mm. (203 dots correspond to 1”.)
1. Perform steps 1-6 on page 2-
51 to enter the Factory Mode menu. See “(3-2) How to enter
the Factory/Service Mode”.
2. Press the [PAUSE] key until “Mach Hor Pos” submenu is printed.
Do you want to change “Factory Mode Menu” items?
Y es=(PAUSE) No=(STOP) Exit=(MODE)
Through Sensor Position +000dos
S ave=(PAUSE) Next Digit=(FEED) Change value=(STOP) Exit=(MODE)
:
:
Mach Hor Pos +00dots
Save=(PAUSE) Next Digit=(FEED) Change value=(STOP) Exit=(MODE)
Note: In the actual printing, the cursor “^” will be printed instead of “ (underline)”.
3. To set the value to 16 (0 plus 16), press the [FEED] key to move the cursor to the next
digit (+00), and then press the [STOP] key once to specify “1”.
Each time you press the [STOP] key, the value of the current digit with the cursor will scroll
(0, 1, 2, 3, 4, ...., 9, 0).
4. Next, press the [FEED] key to move the cursor to the next digit (+10).
The changed value is printed.
Mach Hor Pos +10dots
Save=(PAUSE) Next Digit=(FEED) Change value=(STOP) Exit=(MODE)
5. Press the [STOP] key 6 times to specify “6”.
Each time you press the key, the value will scroll (8, 9, 0, 1, ...., 6).
6. To save the set value, press the [PAUSE] key.
The set value will be printed. Be sure that the new value is “16”, and then press the
[MODE] key to exit the item.
* If the value is not the one you expected, repeat above operation.
Mach Hor Pos +16dots
Save=(PAUSE) Next Digit=(FEED) Change value=(STOP) Exit=(MODE)
1 mm
[
Front
]
Head
+