Maintenance and Service Guide 9-11
Addendum 108431-001 (11-88) to
Manual No. 108033-003
7. If you applied the patch, place the patched
files on the working copies of the appropri-
ate NetWare diskettes. Use the NETGEN
program to generate and link the NetWare
operating system and utilities.
8. Run COMPSURF to perform a surface
analysis on the server fixed disk drives.
The following are appropriate responses to
COMPSURF prompts:
Format the disk? N
Retain the bad
block list? N
Enter bad blocks? N
Number of sequential At least 1 (one)
passes pass
Random I/O Take the default
operations number
9. Use the “NetWare Installation” option from
the NETGEN Main Menu to install NetWare.
NOTE: When installing NetWare on high
capacity fixed disk drives, the NET-
GEN program may halt and display
the following message:
ABEND: Not enough memory
for disk FAT tables.
The NETGEN memory require-
ments does not leave enough
memory to store the File Allocation
Table for large SYS: volumes. The
solution is to avoid the “NetWare
Installation” choice on the NET-
GEN Main Menu and install the
software manually.