Dell HR675 Server User Manual


 
About Your System 21
E1226 PCI Rsr 1.5V
PwrGd
1.5V Riser Card Power Good
failure.
See "Getting Help" on
page 175.
E1229 CPU # VCORE Processor # VCORE voltage
regulator has failed.
See "Getting Help" on
page 175.
E122A CPU VTT PwrGd Processor # VTT voltage has
exceeded the allowable
voltage range
See "Getting Help" on
page 175.
E1310 RPM Fan ## RPM of specified cooling
fan is out of acceptable
operating range.
See "Troubleshooting
System Cooling
Problems" on page 145.
E1311 FAN MOD ##
RPM
RPM of specified cooling
fan module is out of
acceptable operating range.
See "Troubleshooting
System Cooling
Problems" on page 145.
E1313 Fan
Redundancy
One or more cooling fans
has failed. Cooling fan
redundancy has been lost.
See "Troubleshooting
System Cooling
Problems" on page 145.
E1410 CPU # IERR Specified microprocessor is
reporting an internal error.
See your system’s
Information Update tech
sheet located on
support.dell.com for the
most current system
information. If the
problem persists, see
"Getting Help" on
page 175.
Table 1-5. LCD Status Messages (continued)
Code Text Causes Corrective Actions