Dell HR675 Server User Manual


 
About Your System 27
E201C SMI Init System management
interrupt (SMI)
initialization failure.
See "Getting Help" on
page 175.
E201D Shutdown Test BIOS shutdown test failure. See "Getting Help" on
page 175.
E201E POST Mem Test BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 146. If the problem
persists, see "Getting
Help" on page 175.
E201F DRAC Config Remote Access Controller
(RAC) configuration failure.
Check screen for specific
error messages. Ensure
that RAC cables and
connectors are properly
seated. If problem
persists, see your RAC
documentation.
E2020 CPU Config CPU configuration failure. Check screen for specific
error messages.
E2021 Memory
Population
Incorrect memory
configuration. Memory
population order incorrect.
Check screen for specific
error messages (see
"Troubleshooting System
Memory" on page 146).
E2022 POST Fail General failure after video. Check screen for specific
error messages.
E2110 MBE DIMM # &
#
One of the DIMMs in the
set implicated by "# & #"
has had a memory multi-bit
error (MBE).
See "Troubleshooting
System Memory" on
page 146.
Table 1-5. LCD Status Messages (continued)
Code Text Causes Corrective Actions