Dell HR675 Server User Manual


 
About Your System 35
PCIe Fatal Error
caused a system
reset: Slot
n
Embedded
Bus#
nn
/Dev#
nn
/Func
n
Please check the
system event log
for details
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number (see
"Installing an Expansion
Card" on page 95). If the
problem persists, see
"Getting Help" on page 175.
Plug & Play
Configuration Error
Error encountered in
initializing PCIe device;
faulty system board.
Install the NVRAM_CLR
jumper and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting Expansion
Cards" on page 159.
Read fault
Requested sector
not found
The operating system
cannot read from the hard
drive or USB device, the
system could not find a
particular sector on the
disk, or the requested
sector is defective.
Replace the USB medium or
device. Ensure that the USB
or hard drive cables are
properly connected. See
"Troubleshooting a USB
Device" on page 138, or
"Troubleshooting a Hard
Drive" on page 153 for the
appropriate drive(s) installed
in your system.
Remote
configuration
update attempt
failed
System unable to process
Remote Configuration
request.
Retry Remote Configuration.
ROM bad checksum =
address
Expansion card
improperly installed or
faulty.
Reseat the expansion card(s)
and expansion card cables. If
the problem persists, see
"Troubleshooting Expansion
Cards" on page 159.
Table 1-6. System Messages (continued)
Message Causes Corrective Actions