D-Link DES-3225G Switch User Manual


 
24-port NWay Ethernet Switch User’s Guide
118 Using the Console Interface
Figure 6-44. Port Packet Error Statistics tabl
Select the desired setting in the Ports field: 1 to 4, 5 to 8, 9
to 12, 13 to 16, 17 to 20, 21-S1P2, or Slot 2 and the desired
increment setting in the Polling Interval field: 2 sec, 5 sec,
15 sec, 30 sec, 1 min, or Suspend.
The statistic counters displayed are defined as follows:
Speed If the link is up, the speed and duplex status will
be displayed; if the link is down “-” will be displayed.
CRC Error The number of frames that fail the CRC
integrity check.
Oversize Frames The number of good frames with
length greater than 1518 bytes and therefore are
greater than the maximum legal length.
Fragments The number of packets less than 64 bytes
with either bad framing or an invalid CRC. These are
normally the result of collisions.