Emerson FM-3 Network Card User Manual


 
165
Parameter Descriptions
In Position
InPosn
This source activates when commanded velocity is zero and the absolute value of the
following error is less than the InPosnWindow for at least the amount of time specified in the
InPosnTime parameter.
In Position Time
InPosnTime
This parameter is the minimum amount of time that commanded motion must be complete
and the absolute value of the following error is less than the InPosnWindow parameter for the
InPosn source to activate.
In Position Window
InPosnWindow
The absolute value of the following error must be less than this value at the completion of a
move for the InPosnTime before InPosn will activate.
Any Command Complete
Jog.AnyCommandComplete
The Jog.AnyCommandComplete bit will activate when either Jog 0 or Jog 1 completes its
deceleration ramp and reaches zero commanded speed. It deactivates when another jog is
initiated.
Minus Activate
Jog.MinusActivate
This destination is used to initiate jogging motion in the negative direction using the jog
parameters of the jog selected by the Jog select input function. Jogging will continue as long
as the destination is active. The motor will decelerate to a stop when the destination is
deactivated. This is level sensitive.
Plus Activate
Jog.PlusActivate
This destination is used to initiate jogging motion in the positive direction using the jog
parameters of the jog selected by the Jog select input function. Jogging will continue as long
as the destination is active. The motor will decelerate to a stop when the destination is
deactivated. This is level sensitive.