Emerson FM-3 Network Card User Manual


 
179
Parameter Descriptions
Torque Limit
TorqueLimitEnable
This destination is used to enable the TorqueLimit. This is level sensitive.
Travel Limit Minus Activate
TravelLimitMinusActivate
This destination is used to activate the travel limit minus fault. It should be assigned to the
travel limit minus sensor. When it is activated the drive will decelerate to a stop using the
deceleration rate defined in the TravelLimitDecel parameter. This is level sensitive.
Travel Limit Minus Active
TravelLimitMinusActive
This source is active when the TravelLimitMinusActivate is active. When this source is active
motion is allowd in the positive direction only.
Travel Limit Plus Activate
TravelLimitPlusActivate
This destination is used to activate the travel limit plus fault. It should be assigned to the travel
limit plus sensor. When it is activated the drive will decelerate to a stop using the deceleration
rate defined in the TravelLimitDecel parameter. This is level sensitive.
Travel Limit Plus Active
TravelLimitPlusActive
This source is active when the TravelLimitPlusActivate is active. When this source is active
motion is allowd in the negative direction only.
Decimal Places
TorqueUnits.Decimal
This parameter is the decimal point location for user torque units.
Units Name
TorqueUnits.Name
The User can specify a torque unit name of up to 12 characters. Default is % Cont.