46
FM-3 Programming Module Reference Manual
Enable Feedforward Check Box
The Enable Feedforward Check Box is used to turn on or turn off feedforward. If checked,
feedforward is active. If unchecked, feedforward is not used.
Position View
The Position View allows you to set up and view the parameters related to drive positioning.
In Figure 32, Position has been selected in the Hierarchy View. The right side of the view is
divided into groups. An explanation of the groups and their functions is provided below.
Figure 32: Position View
Settings Group
Define Home Position
This is the value to which the position command will be set when the Define Home
destination is activated. This is used in applications which do not use a home routine, but
require a known reference point. The units are defined on the User Units View.