Parameter Descriptions
zero when the axis position gets to 360 degrees. (358, 359, 359.999, 0.0000, 1, 2, and so on.)
The rollover point is defined to be exactly the same position as 0.
Selector Input Destinations
Selector.SelectLinesUsed
The selector is a binary to decimal decoder. This parameter selects the number of destinations
(input lines) to be used by the selector. The number of lines used determines the number of
sources (selections) that can be made by the selector; that is 2 input lines can select 4
destinations (selections), 5 input lines can select 32 destinations. Range is 1 to 8.
Select
Selector .#.Select
This source selects Binary inputs to the selector, usually assigned to input lines. This is level
sensitive.
Selection
Selector.#.Selection
This source selects Decimal outputs from the selector, assigned to indexes, homes or
programs.
Initiate
Selector .SelectorInitiate
When this destination is activated, the selector checks the status of all Selector.Select
destinations to determine which Selector.Selection to activate.
ShuntActive
ShuntActive
This source is active when the drive's internal shunt is active (conducting current).
ShuntPowerRMS
ShuntPowerRMS
This parameter models the thermal heating and cooling of the drive internal shunt. This
parameter indicates the percent of shunt capacity utilization and is based on the Heat Sink
RMS value. When this value reaches 100 percent the drive will generate an RMS Shunt
Power Fault. This is only applicable to the EN-208 and EN-214.