Fluke 2640A Network Card User Manual


 
Using Trend Link for Fluke
Getting the Right Look for Your Trend Link Chart
5
5-15
Using the Trend Link Menus 5-17.
The Trend Link menus (below) allow you to modify the chart display appearance
and functionality. This section does not discuss menu functions repeated on the
Control Bar. (See "Using the Trend Link Control Bar.") This section only
summarizes the menu functions. Refer to the Trend Link for Fluke Reference
Manual for complete menu information.
ds245s.bmp
This section contains the following common menu procedures:
Adjusting the Curve Time Scale (X-axis)
Adjusting the Curve Amplitude Scale (Y-axis)
Configuring the Curve Status Display
Curve Preferences
Background Preferences
Real Time Frequency Update
Adding or Changing the Chart Title
Using the Note System
Printing a Chart
Adjusting the Curve Time Scale (X-axis) 5-18.
Complete the following procedure to adjust the curve time scale (X-axis).
1. Double-click the Time Interval Window at the bottom of the chart (see below)
to open the Change Time dialog box.
ds242c.bmp
2. In the Change Time dialog box, enter the time for the curve display, that is,
the time from the left edge to the right edge of the curve. The format is
00:00:00.000 (hours:minutes:seconds.fraction). For example, 00:00:30.000
represents 30 seconds. Click OK. You can only enter a time that is equal to or
less than the overall recorded chart time. For example, if you have been
collecting data for 6 hours, you can enter a number up to 6 hours. (For this
operation, be sure to position the bottom scroll bar to the far-right.)