Gateway 7450R Server User Manual


 
108 Gateway 7450R Server System Manual
Mechanical specifications
The computer conforms to the following mechanical specifications:
Environmental specifications
The following specifications identify maximum environmental conditions. At
no time should the computer run under conditions which violate these
specifications.
Server management Monitoring, alerting, and logging of critical system information
obtained from embedded sensors on the system board, including
thermal levels, voltage levels, fan speeds, and chassis intrusion
monitoring.
Expansion slots Two 64-bit, 66 MHz PCI slots on the riser card
Drive Bays One CD drive bay (drive optional), one diskette drive bay, and three
hot-plug bays (at least one is occupied by a 1-inch high hot-plug
drive).
1U chassis case size 16.73 in. (424.9 mm) x 24.5 in. (622.3 mm) x 1.67 in. (42.42
mm) (WxDxH)
Weight 26.6 lbs (12.1 kg)
Temperature
Nonoperating
Operating
Maximum rate of change = 10° C per hour
-20.0° to 60.0° C (-4° to 140° F)
0° to 40° C (32° to 104° F); derated 0.5° C for every 1000 ft.
(305 m) *
Humidity
Nonoperating
Operating wet bulb
95% relative (noncondensing) at 30° C (86° F)
5%85%Not to exceed 33° C (91.4° F) (with diskette drive
or hard disk drive)
Shock
Operating
Packaged
10.0 g, 11 msec, 1/2 sine
Operational after 30-inch free fall (cosmetic damage may
occur)
* Maximum temperature refers to the inlet air temperature, which is the ambient air
temperature within the rack cabinet, not the air temperature within the room.
8507328.book Page 108 Thursday, February 15, 2001 11:28 AM