Gateway 7450R Server User Manual


 
52 Gateway 7450R Server System Manual
Replacing a fan
Fan 1 is located between the expansion cards and the drive bays and fan 2
is located between the two blowers. See Interior of system on page 5 for the
locations of the fans.
To replace a fan:
1 Use the system management software to determine which fan has failed.
2 Turn off the system and disconnect the power cord and external
peripherals.
3 Open the case. See Opening the case on page 18 and Preventing static
electricity discharge on page 17.
4 Unplug the fan cable from the system board and remove the cable from
the cable clamps.
5 Lift the fan out of the fan bracket. (The fan bracket is not secured to the
chassis and may come out when you remove the fan. Replace it on the
pins on the bottom of the chassis.)
6 Insert the new fan into the fan bracket. Make sure the direction of
rotation and airflow match the direction and airflow of the fan you
removed.
Fan 1
Fan 2
8507328.book Page 52 Thursday, February 15, 2001 11:28 AM