HP (Hewlett-Packard) 2300 Switch User Manual


 
239
Software Fixes
Note
The startup-config file saved under version F.05.05, or later, is NOT backward-compatible with
previous software versions. The user is advised to save a copy of the pre-05.05 startup-config file
BEFORE UPGRADING to F.05.05 or greater, in case there is ever a need to revert back to pre- 05.05
software. Instructions for saving a copy of the startup-config file are found in the "Transferring Switch
Configurations" section of Appendix A in the Management and Configuration Guide (included on
the Product Documentation CD-ROM (PDF format)) that shipped with the switch.
Fixed in release F.05.05
Agent Hang — Agent processes (such as console, telnet, STP, ping, etc.) may stop func-
tioning when the IGMP querier function is disabled, and then re-enabled, on a VLAN that
does not have an IP address configured.
ARP — Changing the IP address of a VLAN does not delete the ARP entry for the old IP
address.
GARP/Event log — Garp event log messages may be garbled.
CLI — The CLI command show arp displays the wrong port number for some ARP entries.
CLI — The CLI command show trunks lists incorrect information for dynamic trunks.
CLI — The CLI command getmib with no parameters returns the message Incomplete
input: - EOI -.
CLI — Unrelated information was shown at the end of the CLI command "show vlan 1"
output.
CLI — Command "no qos" did not reset port priority to "0".
CLI — When reaching the inactivity timeout expiration after typing the CLI command
"enable" in a telnet session at operator mode, the text in the CLI prompt may get corrupted
with text similar to "gfs_alp_104Null Varbind".
CLI — The CLI command "show tech" causes an error message when the command is
executed from within config mode.
CLI — The prompt for saving the config does not handle a DISC character appropriately.
CLI/Timezone — The switch time is wrong if CLI used to set timezone and timezone may
not operate properly after switch is rebooted. West of GMT is now a negative offset and east
of GMT is now a positive offset.