Software Fixes
Crash — If dynamic trunks are configured and the switch is rebooted, the switch may crash
with a message similar to:
->Software exception at rstp_dyn_reconfit.c:243 in -- 'Lpmgr'
Crash — The "show config" CLI command may cause the switch to crash with a message
similar to:
->Software exception "xlate.c:1358 in 'mSess1'
Crash — When hot-swapping transceivers multiple times, the switch may crash with a
message similar to:
-> Software exception at port_sm.c:378 in -- 'mPmSlvCtrl'
Crash — The switch may crash with a message similar to:
-> Software exception at alloc_free.c:545 -- in 'eDrvPoll'
Crash — The switch may crash with a message similar to:
->Asserts in rv.cc line 632
Crash — When adding ports to a manual LACP trunk configuration, the switch may crash
with a message similar to:
-> Assert line 10070 cli_config_action.c
Crash — The switch may crash with a message similar to:
-> Bus Error: HW Addr=0x0000000 IP=0x002fe640 Task='eTelnetd'
This crash has been associated with security/vulnerability test applications such as Nessus.
Event Log — Log messages for trunks and trunk members enhanced to be easier to read.
GVRP — Upstream GVRP neighbor does not pass VLAN information to downstream
neighbor after a topology change.
IGMP — Interoperability issues with some Cisco devices (such as some Cisco Catalyst 5000
& 6000 series switches) cause IGMP groups to be aged out of the switch's IGMP tables
prematurely.
LACP/802.1X — 802.1X and LACP trunks can co-exist on the same port. (Fix is to make
these trunks mutually exclusive.)
LACP — LACP maintains a dynamic trunk with only 1 port configured for the trunk group.