Attempt to init FR on inactive cct
Meaning: The indicated frame relay circuit is not active, yet there was an attempt
to initialize the circuit. This is an internal problem and cannot be
corrected by the user.
Bad Address option combination
Meaning: In the indicated frame relay circuit, the selected combination of
addressing encoding and address length is not compatible. Allowable
combinations are:
Q921 TWO BYTE only
Q922 March 90 TWO BYTE only
Q922 November 90 TWO BYTE
THREE BYTE
FOUR BYTE
Q922 TWO BYTE
TWO + CONTROL
THREE BYTE
THREE + CONTROL
FOUR BYTE
Action: Modify the configuration so that the address encoding and address
length are compatible.
bad configuration file
Meaning: The configuration has an inconsistency or error.
Action: Check the portion of the configuration for the type of circuit named
after “cct” in the object name preceding this message. Correct the
configuration and reboot the router.
Bad full polling; reset to 6
Meaning: In the indicated frame relay circuit, the chosen interval between full
polling parameter is not within the proper range. The proper range is
between 1 and 255 polls. The default value is to send a full status enquiry
every six polling cycles.
Event Log Messages
cct: Circuit Event Messages