HP (Hewlett-Packard) 600 Network Router User Manual


 
Parameters and Options
Adapter Record
Displays a screen with parameters for configuring a V.25bis circuit. For additional
information, refer to Connect When.
Alarm Timer
Sets the time interval between issuing a Status Enquiry or Full Status Enquiry
message and the receipt of a Link Verification or Full Status Report from a Frame
Relay DCE. The timer value must be less than or equal to the value selected for Poll
Interval.
Default: 10
Range: 5 to 30
AppleTalk multicast
DLCI
Refer to ‘‘Multicast Support’’ on page 4-22.
ARP Group Address
Accepts an IP address resolution multicast address. Enter a 10-digit decimal address
to be used for IP address resolution broadcasts or leave blank if the SMDS circuit
does not carry IP traffic.
ARP multicast DLCI
Refer to ‘‘Multicast Support’’ on page 4-22.
Auto Enable
Enables or disables the initial state of the LAN circuit.
This circuit-specific Auto Enable parameter works in conjunction with the global
Auto Enable parameter found on the Global Parameters screen in the System
configuration menu to enable or disable the LAN circuit when the router boots.
When the global Auto Enable parameter is set to No, the setting of the circuit-
specific Auto Enable parameter is unconditionally disabled.
When the global Auto Enable parameter is set to Yes, the setting of the circuit-
specific Auto Enable parameter determines whether the circuit is automatically
enabled.
Default: Yes
No
Disables the circuit. (To enable the circuit after the router boots, you must use the
NCL Interpreter’s Enable command.)
Yes
Automatically enables the circuit if the global Auto Enable parameter is enabled.
Circuit
Parameters
4
Circuit Parameters
Parameters and Options
4-5