HP (Hewlett-Packard) 600 Network Router User Manual


 
LCP Active-Open
Determines whether Point-to-Point establishes the LCP connection.
Note: At least one of the Point-to-Point peers must be configured to “actively” open
the LCP connection.
Default: Yes
Yes
The Point-to-Point circuit attempts to establish the LCP connection as soon as the
physical link is ready.
No
The Point-to-Point circuit waits for the remote peer to establish the LCP connection.
LCP Auto Restart
Determines whether the Point-to-Point protocol attempts to re-establish an LCP
connection after the link is declared down.
Yes
The Point-to-Point circuit attempts to re-establish an LCP connection.
No
The Point-to-Point circuit does not attempt to re-establish an LCP connection.
Link Idle Timer (T3)
Sets the idle time, in seconds, to wait before disconnecting the Point-to-Point circuit.
Default: 3 (seconds)
Range:
Local Address
Accepts a unique decimal value from 00 through 99 when entering an explicit Point-
to-Point (non x.25) address. For more information, refer to “Point to Point Address,”
and specifically, the Explicit option.
Default: 07
Range: 00 to 99.
Note: Avoid the conventional address values of 01 or 03.
Local LAN Address
Accepts the MAC address of the source pass-thru circuit. This parameter appears
when the Data Link Layer protocol parameter is set to Pass Thru.
LQM Time (secs)
Sets the link-quality-monitoring report period in seconds.
Default: 0 (seconds)
Disable: 0
Range:
Circuit
Parameters
4
Circuit Parameters
Parameters and Options
4-17