Precedence
Assigns a priority values to a filter—the higher the precedence, the greater the
priority. You can construct up to 31 filters per bridge circuit group. The
Precedence value is used when an incoming packet meets multiple filter rules. In
such an instance, the filter with the highest priority is applied to the frame.
Default: 31
Range: 1 to 31
Priority
In the event of identical-cost circuit groups, the spanning tree algorithm select
the circuit group with the better (lower) priority value. Priority is only
meaningful if the spanning tree algorithm is enabled.
Default: 128
Options
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 16, 32, 64, 127, 128, 129, 255
Protocol ID/Org.
Code (high)
Sets the upper boundary of the range for filtering a frame based on the contents
its Protocol ID/Organization Code field.
Options
Leave this field blank if you do not want to filter a frame based on its Protocol
ID/Organization Codes.
If you are filtering a single Protocol ID/ Organization Code, leave this field
blank and enter the Protocol ID/ Organization Code in the Protocol ID/Org.
Code (low) field.
If you are filtering a range of Protocol ID/Organization Codes, enter the
highest Protocol ID/Organization Code in the range.
If you want to establish a range of Protocol ID/Organization Codes with a filter
list, leave this field blank and enter the name of a Protocol ID/Organization
Code list in the Protocol ID/Org. Code (low) field.
For more information, refer to “Protocol ID/Org. Code (low)”.
Note: The Protocol ID/Org. Code (high) parameter is also displayed when
creating a Protocol ID/Organization Code list.
Protocol ID/Org.
Code (low)
Sets the lower boundary of the range for filtering a frame based on the contents
of its Protocol ID/Organization Codes.
Options
If you do not want to filter Protocol ID/Organization Codes, leave this field
blank.
If you are filtering a single Protocol ID/Organization Code, enter the Protocol
ID/Organization Code in this field and leave the Protocol ID/Org. Code (high)
field blank .
Bridge
Parameters
6
Bridge Parameters
Parameters and Options
6-17