To Recalibrate the Plotter
1 Choose your media type (sheet or roll). If recalibrating for a non-standard media
type, use that type. Otherwise, HP Matte Film will give greatest accuracy.
2 Choose your media size. Sheet media must be either E/A0 or D/A1.
3 Go to
Recalibrate in the front-panel menus, as shown above left.
4 Choose
Create pattern. The message Calibrating is displayed. If sheet media is
loaded, this will be ejected. If roll media is loaded, you are asked to remove it.
5 When prompted, load your media, using the normal procedure. If using sheet
media, load it in portrait orientation, unless you chose D/A1-size media for an
E/A0-size plotter, in which case load it in landscape orientation.
6 When the calibration plot is finished, remove it.
7 Unload any unplotted media.
8
Rotate the calibration plot 90_ counterclockwise and reload it printed side
down, so that the black arrows go into the plotter first. NOTE: Even if you
selected roll media in step 5, this time you must select sheet media.
123
0030
9 Go to Recalibrate again and, this time, choose Measure pattern.
10 When the plotter has finished measuring and has ejected the sheet, STATUS/Ready
is displayed. The recalibration routine is finished.
To Restore the Factory’s Calibration
From the Accuracy menu, choose Restore factory. That’s all.
Reconfiguring Your Plotter
Recalibrating the Plotter for Accuracy