HP (Hewlett-Packard) 750C Plus Scanner User Manual


 
750C Plus
9-14
Company confidential. Murillo/Ravillo User’s Guide. Final Freeze Status: Frozen
This is the cyan on page 9-14 (seq: 176)
This is the black on page 9-14 (seq: 176)
If the Plot Is Distorted or Unintelligible
The interface cable between your computer and the plotter could be faulty. Try
another cable to see if the problem is corrected.
If you are using a serial interface between the plotter and your computer, make
sure the plotter’s serial interface settings match the settings and requirements of
your software and hardware. See page 1-29.
If One Plot Overlays Another Plot on the Same Sheet
The I/O Setup / I/O Timeout setting may be too long. Decrease the setting and
plot again. See page 7-9.
If
Device setup / Lang is set to 7586,HP–GL/2 (the default), try changing the
Terminator setting and send the files again.
If Pen Settings Seem To Have No Effect
Either you have changed them in Pen settings / Define palette but forgotten to
select that palette in
Pen settings / Palette,
or you expected the software-driven pen settings but the front panel Pen
settings / Palette
is not set to Software.
See page 5-6.
If the Plotter Produces a Black and White Plot When You
Expected a Color Plot
Check the front panel Color/Mono setting, and the equivalent setting in your
software.
Troubleshooting
Solving Problems with Plot Position or Content
!