HP (Hewlett-Packard) MSL6000 series Computer Drive User Manual


 
Troubleshooting104
0B02 Public Ethernet Set IP Error
(The library could not set the IP
parameters)
Make sure a valid Ethernet address has
been programmed using the LCD touch
display. (Menu -> Maintenance ->
Library)
Reboot the library
1001 SCSI Firmware Error
(Internal SCSI task processing error.
Unexpected state or hardware status.)
Turn off power to the library and inspect
connectors and cables.
Check the SCSI cable connections to
make sure they are secured.
Make sure the library controller board
has SCSI termination.
1002 SCSI FIFO Empty
(The SCSI controller data FIFO is empty
but should contain more data bytes.)
Turn off power to the library and inspect
connectors and cables.
Check the SCSI cable connections to
make sure they are secured.
Make sure the library controller board
has SCSI termination.
1003 SCSI FIFO Error
(The SCSI controller data FIFO should be
empty but still contains data bytes.)
Turn off power to the library and inspect
connectors and cables.
Check the SCSI cable connections to
make sure they are secured.
Make sure the library controller board
has SCSI termination.
1004 SCSI Gross Error
(The SCSI controller detected a gross error
condition. Invalid SCSI bus phase or
DMA error.)
Turn off power to the library and inspect
connectors and cables.
Ensure SCSI options are set correctly.
Check the SCSI cable connections to
make sure they are secured.
Make sure the library controller board
has SCSI termination.
Check host SCSI cable and connections.
Table 10 Fault Symptom Codes (continued)