HP (Hewlett-Packard) MSL6000 series Computer Drive User Manual


 
Troubleshooting126
503D Drive Status Fail
(Cleaning operation failed because the
library could not retrieve drive status.)
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
Ensure the drive shows good status
through the drive status window.
6001 Inter-Module Unknown Event
(Inter-module communication failure.)
Press Enter to reboot.
Check pass-through connections.
Check network connections to the
network router.
6002 Inter-Module no command matching
response
Verify operation and retry.
Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
6003 Inter-Module command length
(Incorrect command length.)
Verify operation and retry.
Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
6004 Inter-Module loopback buffer mismatch Cycle power to the library or reboot by
using the LCD touch display.
•Retry operation.
6005 Inter-Module bad data length
(Incorrect data length.)
Verify operation and retry.
Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
6006 Inter-Module bad packet length
(Incorrect packet length.)
Verify operation and retry.
Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
6007 Inter-Module failed to allocate TCP buffer Power cycle the library.
Check pass-through connections.
6008 Inter-Module pending table full Power cycle the library.
Retry the operation.
7001 Command response from unexpected
source
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
Table 10 Fault Symptom Codes (continued)
FSC Message ERP