7021 SCSI response not matched to a known
command
(A command response was received from
a SCSI task, but the original command
opcode could not be determined.)
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
7022 Unexpected state after NonVolConfig
cmd
(After successfully completing a
NonVolConfigPut command, the current
state of the save operation was unknown.)
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
7023 Unexpected state after SCSI mode cmd
(After successfully completing a
SCSIUpdateMode Parameters command,
the current state of the save operation was
unknown.)
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
7024 Unexpected state after SCSI init cmd
(After successfully completing a
SCSIInitCommand, the current state of the
save operation was unknown.)
Press the Enter button clear the
message.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure the drive shows good status
through the drive status window.
7025 Message is Invalid Map Conversion
Parameters
(GUI Map Parameters are corrupt or
invalid.)
Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
8001 Cartridge reject recovery failed Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Cycle power to the library or reboot
using the GUI touch screen.
Check the tape cartridge used in the last
operation for damage.
Table 10 Fault Symptom Codes (continued)