HP (Hewlett-Packard) MSL6000 series Computer Drive User Manual


 
MSL6000 series tape library user guide 133
9003 Master pass-thru opto failed.
(The master module opto sensor was not
detected during the power-up
Pass-Through module inventory.)
Press the Enter button to reboot.
Run the sensor test, checking appropriate
sensor.
Determine if the pass-through may have
been plugged or unplugged while power
was on to the library.
Reinitialize or power-cycle the master it is
connected to. Ensure the pass-through is
functioning by observing whether or not
the pass-through car moves to either end
of the pass-through smoothly.
A001 SMX send error
(An attempt to place a message on a
task’s exchange generated a kernel
error.)
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
A002 SMX receive error
(An attempt to receive a message from a
task’s exchange generated a kernel
error.)
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
A003 Comm free list empty
(An attempt to acquire a message from
the free pool failed because the pool is
empty.)
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
A004 Invalid comm. put attempt
(An attempt to place a message on a
task’s exchange failed.)
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
A005 Invalid comm. get attempt
(An attempt to receive a message from a
task’s exchange failed.)
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
A006 Comm initialization error
(The Comm manager could not be
initialized at power-up because system is
out of memory.)
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
A007 Put of a NULL comm. Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
Table 10 Fault Symptom Codes (continued)
FSC Message ERP