HP (Hewlett-Packard) MSL6000 series Computer Drive User Manual


 
MSL6000 series tape library user guide 65
Init Element Status Lets you specify the library’s response to the SCSI
INITIALIZE ELEMENT STATUS command. The
possible settings are No Inventory, Force Inventory, and
Force Label Scan. The default is Force Inventory.
Test Unit Ready
Reporting
Lets you specify the response to a TEST UNIT READY
command if the library is in Sequential Mode. The
possible settings are Standard or Custom. The default is
Custom.
Device Capability Page
Length
Lets you choose between two lengths of the mode
sense/select device capabilities page (SCSI page 1Fh),
which are Short (14 bytes) and Long (18 bytes), to
accommodate different SCSI device implementations of
this page. The default is Short (14 bytes).
Transport Element
Base Address
Lets you set the base address for the robotics mechanism.
The default is 0x0.
Storage Element
Base Address
Lets you set the base address for the magazine slots. The
default is 0x20.
Transfer Element
Base Address
Lets you set the base address for the tape drives. The
default is 0x1E0.
Import/Export Element
Base Address
Lets you set the base address for the mail slot. The default
is 0x1C0.
Product Identification
(PID)
Lets you specify the response of the library’s robotics to the
SCSI INQUIRY command in the Product Identification
field. The default is MSL6000 Series.
Vendor Identification
(VID)
Lets you specify the response of the library’s robotics to the
SCSI INQUIRY command in the Vendor Identification
field. The default is HP.
Post Recovered Errors Lets you specify whether or not recovered errors are
posted. The default is Disabled.
Table 6 View SCSI Options (continued)
Option Description