3016 Drive Status Failure Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Check cabling.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
3017 Drive In Flux Timeout
(Time-out waiting for drive to clear the full
status.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Check cabling.
Load/unload a cartridge to the drive to
verify.
Run the cartridge cycle diagnostic to
verify.
3018 Drive Load Retry Failed
(SLTO drive fail to load, detected in drive
task.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat the drive.
Check cabling.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used int he last
operation for damage.
Run the cartridge cycle diagnostic to
verify.