Temperature, humidity, and altitude
The following table provides temperature, humidity, and altitude specifications for
the 4560SLX Tape Library.
Table 15. Temperature, humidity, and altitude specifications (non-operating - long term)
Non-operating - long term (unpacked or packed)
Dry Bulb Temperature -40°C to 60°C
Temp Gradient 20°C/hr. (across the range)
Temperature Shock 15°C (over 2 min.)
Wet Bulb Temperature 30°C
Relative Humidity 5% to 95% (non-condensing)
Humidity Gradient 10%/hr
Altitude (sea level) -1000 ft. to +10,000 ft.
Table 16. Temperature, humidity, and altitude specifications (transit - short term)
Transit - short term (packed 7 days)
Dry Bulb Temperature -40°C to 60°C
Temp Gradient 25°C/hr. (across the range)
Temperature Shock 15°C (over 2 min.)
Wet Bulb Temperature 30°C
Relative Humidity 5% to 95% (non-condensing)
Altitude (sea level) -1000 ft. to +10,000 ft.
Shock
The following tables provide operating, non-operating, transit/storage, and
physical drop test shock specifications for the 4560SLX Tape Library.
Table 17. Shock specifications (operating)
Operating (within spec - no damage)
Peak Acceleration 1.5 G’s
Duration 11 ms
Waveshape 1/2 sine pulses
Application X,Y,Z axes, repeat 3 times
Table 18. Shock specifications (non-operating)
Non-operating (unpacked - no damage)
Peak Acceleration 25 G’s
Duration 11 ms
Waveshape 1/2 sine pulses
Application X,Y,Z axes, repeat 3 times
Appendix C. Specifications 93