IBM 4560SLX Label Maker User Manual


 
Temperature, humidity, and altitude
The following table provides temperature, humidity, and altitude specifications for
the 4560SLX Tape Library.
Table 15. Temperature, humidity, and altitude specifications (non-operating - long term)
Non-operating - long term (unpacked or packed)
Dry Bulb Temperature -40°C to 60°C
Temp Gradient 20°C/hr. (across the range)
Temperature Shock 15°C (over 2 min.)
Wet Bulb Temperature 30°C
Relative Humidity 5% to 95% (non-condensing)
Humidity Gradient 10%/hr
Altitude (sea level) -1000 ft. to +10,000 ft.
Table 16. Temperature, humidity, and altitude specifications (transit - short term)
Transit - short term (packed 7 days)
Dry Bulb Temperature -40°C to 60°C
Temp Gradient 25°C/hr. (across the range)
Temperature Shock 15°C (over 2 min.)
Wet Bulb Temperature 30°C
Relative Humidity 5% to 95% (non-condensing)
Altitude (sea level) -1000 ft. to +10,000 ft.
Shock
The following tables provide operating, non-operating, transit/storage, and
physical drop test shock specifications for the 4560SLX Tape Library.
Table 17. Shock specifications (operating)
Operating (within spec - no damage)
Peak Acceleration 1.5 G’s
Duration 11 ms
Waveshape 1/2 sine pulses
Application X,Y,Z axes, repeat 3 times
Table 18. Shock specifications (non-operating)
Non-operating (unpacked - no damage)
Peak Acceleration 25 G’s
Duration 11 ms
Waveshape 1/2 sine pulses
Application X,Y,Z axes, repeat 3 times
Appendix C. Specifications 93