v Verify the availability of all required parts and media for the Licensed
Internal Code
__ 3. On the target system, verify the availability of a compatible alternate IPL
device (CD-ROM or tape unit attached to the system bus 1). If the system
uses an alternate installation device (CD-ROM, DVD, or tape unit attached
to a bus other than the system bus 1) for installation or restore operations,
ensure the availability of the location information for that device.
Note: If a tape unit is attached to a bus other than the system bus 1, record
the following information about the tape unit location:
v Type and model
v System bus
v System card
This information is necessary to set up and enable the tape unit as an
alternate installation device. For more information about alternate
installation devices, go to the Software Installation book.
When all of the above items are in place, the hardware service representative
should do the following procedures:
__ 1. Perform the model upgrade using the Customized Universal Installation
Instructions (CUII) that came with the upgrade.
__ 2. Follow the Return Material Equipment Report (RMER) shipped with the
hardware upgrade for instructions on what to do with the parts.
__ 3. Perform any contracted relocation or rearrangement services prior to
returning the system to the customer for their use.
__ 4. Perform normal clean-up and housekeeping tasks. This includes proper
reporting of time and activities, including any fee-based services delivered.
After the hardware is installed, the customer should do the following:
In the next few steps the customer will be required to use the information from the
service representative to finish the resource management on the new server. The
goal of these steps is to ensure the server is set up and running to the customers
needs.
__ 1. Ensure that you received the source systems label locations print out from
the hardware service representative. (Refer to step 8 on page 26). This is
used to get the hardware resources correctly assigned to resource names.
__ 2. Continue the initial program load (IPL) by selecting option 1 from the IPL
or Install the System screen.
Notes:
a. You might see a disk unit format optimize warning message. IBM
suggests that you handle this disk optimization and protection later. See
step 17 on page 32.
b. If the Add All Disk Units to the System ASP screen appears, IBM
recommends that you wait and add the disk units at step 19 on page 32.
Note:
Changing the QIPLTYPE system value may result in receiving the system
reference code (SRC) A900 2000.