IBM As400e 940 Server User Manual


 
v The display has label information, but the source system did not
have label information in that location.
v The source system label information does not match the information
found in the Label column on the display.
v *NONE appears in the Label column on the display, and there is label
information for the source system.
Note: When *NONE appears in the Label column for a controller or
device that was added or upgraded, select option 2. Then
select the correct label description from the list provided. If
any problems arise from this, call your service provider.
v *INCORRECT or *INVALID appears in the Label column.
This means that the type and model number of the hardware
resource information does not match the type and model of the
configuration description that is currently associated with that
resource. The system cannot vary on the configuration description.
v *INCORRECT where the physical location is also **.
This identifies a controller or device description that no longer has a
valid resource on the system.
e. Do you have any locations that do not match the label information on
the system?
Note: It is normal for the resource names to change during the upgrade
process. Do not use the resource name information from other
displays to match the labels.
YES - Go to step 9f.
NO - The system label information is the same as the (physical) label.
Go to step 10 on page 31.
f. On the Change Description Label Locations display, type 2 in the Opt
column for each location that requires a label change. Press the Enter
key.
Note: You may make more than one selection at a time, but if More...
appears on the bottom of the display, do not press the Enter key.
Page forward to select the remaining labels.
g. The Change Description Label display appears.
A list of possible label names is shown. To select the label name (on the
display) that matches the label that was on the source system, perform
the following:
v Type 1 in the Opt column for each location that you want to change.
v Press the Enter key.
Note: If you cannot find the label (on the display) that matches the
label on the source system, contact your hardware service
representative.
h. If you chose to change more than one item, the Change Description Label
display appears for the next label. A message at the bottom of the
display indicates whether the previous change was successful.
i. For all the labels that need a change, repeat the previous three steps.
30 AS400e 940x RISC-to-RISC Road Map V4R5