IBM SA38-0512-03 Server User Manual


 
Table 4-1 (Page 3 of 11). Firmware Error Codes
Error Code Function /
Description
Repair Action/Possible Failing FRU
20E0000B EEPROM write
problem
1. Power Off/On machine
2. Replace System Planar
20E0000C EEPROM read
problem
1. Power Off/On machine
2. Replace System Planar
20E00017 Cold boot needed
for password entry
Power Off/On machine
Informational
20EE0003 IP parameter
requires 3 dots "."
Enter valid IP parameter
Example: 000.000.000.000
20EE0004 Invalid IP parameter Enter valid (numeric) IP parameter
Example: 000.000.000.000
20EE0005 Invalid IP parameter
(>255)
Enter valid (numeric) IP parameter in the range of 0 to
255
Example: 255.199.002.000
20EE0006 No SCSI controllers
present
The System Planar should always have (at least) the
2 integrated PCI SCSI controllers
1. Replace System Planar
20EE0007 Keyboard not found 1. Plug in keyboard
2. Replace System Planar
20EE0008 No configurable
adapters found in
the system
This warning occurs when the selected SMS function
cannot locate any devices/adapters supported by the
function. If a supported device is installed:
1. Replace the device or adapter
2. Replace System Planar
Chapter 4. Error Code to FRU Index for the Model 150 4-3