Table 4-3 (Page 13 of 13). Firmware Checkpoints
Checkpoint
(hex)
Description Repair Action
E243 Set up Grackle
configuration
registers
1. Replace System Planar
E244 Enable system
speaker and send a
beep
1. Replace System Planar
E246 System firmware
corrupted, take
recover path
1. Replace System Planar
E247 Capture DIMM
SPDs into NVRAM
1. Replace System Planar
E249 Enter recover path's
main code
1. Replace System Planar
E24C L2 cache array test
fails. System hangs.
1. Replace System Planar
E24D L2 cache array test
fails. System
hangs.
1. Replace System Planar
E298 Take firmware soft
load path
1. Replace Softload Image
E299 Start C code
execution.
See “Unresolved problems” on page 4-26
E3xx Memory test See “MAP 1240: Memory Problem Resolution” on
page 2-12
E440 Validate nvram,
initialize partitions as
needed
1. Verify that the system firmware is at the current
release level. Update as necessary.
2. See “Unresolved problems” on page 4-26
E441 Generate /options
node nvram
configuration
variable properties
1. Verify that the system firmware is at the current
release level. Update as necessary.
2. See “Unresolved problems” on page 4-26
E442 Validate nvram
partitions
1. Verify that the system firmware is at the current
release level. Update as necessary.
2. See “Unresolved problems” on page 4-26
E443 Generate nvram
configuration
variable dictionary
words
1. Suspect a system firmware problem. If problem
persists, verify that the system firmware is at
current release level, update downlevel system
firmware.
2. See “Unresolved problems” on page 4-26
Chapter 4. Error Code to FRU Index for the Model 150 4-25