Table 4-1 (Page 6 of 11). Firmware Error Codes
Error Code Function /
Description
Repair Action/Possible Failing FRU
25010000 No diskette in drive Insert diskette containing firmware update file
25010001 Diskette seek error 1. Retry function.
2. Replace diskette drive
3. Replace diskette cable
4. Replace System Planar
25010002 Diskette in drive
does not contain an
*.IMG file
Insert diskette with firmware update file
25010003 Cannot open
OPENPROM
package
1. Replace System Planar
25010004 Cannot find
OPENPROM node
1. Replace System Planar
25010006 System id does not
match image system
id
Make sure correct firmware update diskette is being
used with this system.
25010007 Image has bad CRC 1. Replace firmware updated diskette
25010008 Flash is write
protected, update
cancelled
1. Power Off/On machine and retry
2. Replace System Planar
25010009 Flash module is
unsupported or not
recognized
Make sure correct firmware update diskette is being
used with this system.
2501000A Flash write
protected.
1. Power Off/On machine and retry
2. Replace System Planar
NVRAM problems
NVRAM problem resolution:
1. Errors reported against NVRAM can be caused by low Battery voltage and (more rarely) power
outages that occur during normal system usage. With the exception of the 25A80000 error, these
errors are really just warnings that the NVRAM data content had to be re-established and do not
require any FRU replacement unless the error is persistent. When one of these errors occurs,
any system customization (eg. boot device list) information has been lost, the system may need
to be re-configured.
2. If the error is persistent, replace the battery.
3. If the error is persistent after battery replacement, or the error code is 25A80000, replace the
System Planar.
25A80000 Initialization failed,
device test failed
Refer to NVRAM problem resolution above
25A80001 init-nvram invoked,
ALL of NVRAM
initialized
Refer to NVRAM problem resolution above
4-6 7043 43P Series Service Guide