Table 4-1 (Page 7 of 11). Firmware Error Codes
Error Code Function /
Description
Repair Action/Possible Failing FRU
25A80002 init-nvram invoked,
some data partitions
may have been
preserved
Refer to NVRAM problem resolution above
25A80011 Data corruption
detected, ALL of
NVRAM initialized
Refer to NVRAM problem resolution above
25A80012 Data corruption
detected, some data
partitions may have
been preserved
Refer to NVRAM problem resolution above
25A80100 NVRAM data
validation check
failed
Power Off/On machine and retry the operation before
replacing any system components.
Refer to NVRAM problem resolution above
25A80201 Unable to expand
target partition while
saving configuration
variable
Refer to NVRAM problem resolution above
25A80202 Unable to expand
target partition while
writing error log
entry
Refer to NVRAM problem resolution above
25A80203 Unable to expand
target partition while
writing VPD data
Refer to NVRAM problem resolution above
25A80210 Setenv/$Setenv
parameter error -
name contains a null
character
Refer to NVRAM problem resolution above
25A80211 Setenv/$Setenv
parameter error -
value contains a null
character
Refer to NVRAM problem resolution above
Chapter 4. Error Code to FRU Index for the Model 150 4-7