Table 4-3 (Page 11 of 13). Firmware Checkpoints
Checkpoint
(hex)
Description Repair Action
E1EE Jump to composite
image
See “Unresolved problems” on page 4-26
E1EF Erase flash See “Unresolved problems” on page 4-26
E1F0 Start O.B.E. See “Unresolved problems” on page 4-26
E1F1 Begin selftest
sequence on boot
device(s)
See “Unresolved problems” on page 4-26
E1F2 Power On Password
prompt
Prompt should be visible on the system console.
If a console is attached but nothing is displayed on it,
follow the steps associated with “All display problems”
in the Entry MAP tables.
E1F3 Priviledged Access
Password prompt
Prompt should be visible on the system console.
If a console is attached but nothing is displayed on it,
follow the steps associated with “All display problems”
in the Entry MAP tables.
E1F5 Build boot device list See “Unresolved problems” on page 4-26
E1F6 Determine boot
device sequence
See “Unresolved problems” on page 4-26
E1F7 No boot image
located
See “Unresolved problems” on page 4-26
E1FB Scan SCSI bus for
attached devices
See “Unresolved problems” on page 4-26
E1FD Default Catch The operator panel will alternate between the code
“E1FD” and another “Exxx” code where “Exxx” is the
initialization point at which the error occurred. If the
“Exxx” code is not listed in this table, go to “MAP 1540:
Minimum Configuration”
E201 Setup PHB BARC
addresses
1. Replace System Planar
E202 Initialize PHB
registers and PHB's
PCI configuration
registers
1. Replace System Planar
E203 Look for PCI to ISA
bridge
1. Replace System Planar
E204 Setup ISA bridge
PCI config. registers
and initialize
1. Replace System Planar
Chapter 4. Error Code to FRU Index for the Model 150 4-23