Impulse PCW-5181 Computer Drive User Manual


 
Chapter 3 - Connecting and Installing Your Impulse
3-10
G. Mounting the Impulse Drive
This section includes installation requirements, Impulse dimensions, installing and removing
mounting brackets, and mounting the Impulse on a DIN rail.
Environmental and Installation Requirements
Operating Ambient Temperature: Max. 50º C (122º F) @ 4 Amps
Storage Temperature: Max. 65º C (149º F)
Not intended for use in humidity above 95% (non-condensing), or at altitudes greater than
3,048 meters [10,000 ft.]
Heat Dissipation @ 4 A (typical): 32 Watts
Leave 6 inches above and below drives for airflow and wiring.
Leave 0.1 inch between drives for easier mounting.
Air supplied to the Impulse must be uncontaminated.
Mounting Arrangements
The illustration on the right shows an example
of an acceptable mounting arrangement.
COM
PORT
I/O
COM
PORT
I/O
COM
PORT
I/O
COM
PORT
I/O
COM
PORT
I/O
COM
PORT
I/O
COM
PORT
I/O
COM
PORT
I/O
COM
PORT
I/O
COM
PORT
I/O
6.0 in.