62 Chapter 6 System Parameters Menu
Section 6.6 Editing Parameters
6.6 Editing Parameters
This option allows you to edit NAR SSA parameters.
Display Action
To access the extended menu, restart the terminal
by pressing [1] + [CAN] + [OK]; while the terminal
is starting up, access the extended menu by
pressing the [1] and [3] keys simultaneously.
Extended Menu
Serialnum Inject
System Config
System Info
Supervisor Menu
Press [], [], [], [Enter] to select Supervisor
Menu.
Enter Password:
Key password [2] [6] [3] [4], then press [Enter].
Supervisor Menu
Change Password
Application File
Security
Sys Parameters
Press [], [], [], [Enter] to select Sys
Parameters.
Sys Parameters
Download Method
Download Port
Setup Port
Auto Detect
Parameter Editor
Press [] four times, and then press [Enter] to
select Parameter Editor.
Parameter ID:
Enter the parameter ID (maximum three digits).
Updating
The following table lists the parameter ID numbers, descriptions, and values. This table is from
the internal document, NAR SSA Library: Security Part, version 1.23.
The system parameter file is a public file that resides at the root directory of the terminal’s
System & Security Application. This file records the system parameter settings made through
the supervisor menu. The financial application is allowed to read from this file.
Each parameter occupies 16 bytes in the parameter file. A null terminator is required and
saved for character strings, except when the string length is 16. In such case, only 16 bytes of
data are saved.