Ingenico 6500 User’s Guide 77
7.7 Testing the USB Port
This feature tests the USB connection.
Display Action
To access the extended menu, restart the terminal
by pressing [1] + [CAN] + [OK]; while the terminal
is starting up, access the extended menu by
pressing the [1] and [3] keys simultaneously.
Extended Menu
Serialnum Inject
System Config
System Info
Supervisor Menu
Diagnostic Menu
Press [], [Enter] to select Diagnostic Menu.
Diagnostic Menu
Display
Keypad
Beeper
RS232
Tailgate
USB
Press [], [Enter] to select USB.
USB Diagnostic
Connect USB Port OK
Start PC App then
Push OK Key to send
1. From the HOST, start uloop.exe.
2. From the terminal, press [Enter].
USB Diagnostic
MESSAGE n
Send . . .
The results of the test display. To exit, press [Can].