Intel SE8500HW4 Server User Manual


 
Intel® Server Board Set SE8500HW4 Error Handling
Revision 1.0
Intel order number D22893-001
113
Code Description
0xE2 Initial memory found, configured, and installed correctly
0xE,
0xE3
Reserved for initialization module use (PEIM)
DXE Core:
0xE4 Entered EFI driver execution phase (DXE)
0xE5 Started dispatching drivers
0xE6 Started connecting drivers
DXE Drivers:
0xE7 Waiting for user input
0xE8 Checking password
0xE9 Entering the BIOS setup
0xEA Flash update
0xEE Calling Int 19. One beep unless silent boot is enabled.
0xEF Unrecoverable Boot failure/S3 resume failure
Runtime Phase/EFI OS Boot:
0xF4 Entering Sleep state
0xF5 Exiting Sleep state
0xF8 OS has requested EFI to close boot services
0xF9 OS has switched to virtual address mode
0xFA OS has requested the system to reset
PEIM/Recovery:
0x30 Crisis recovery has been initiated because of a user request
0x31 Crisis recovery has been initiated by software (corrupt flash)
0x34 Loading crisis recovery capsule
0x35 Handing off control to the crisis recovery capsule
0x3F Unable to complete crisis recovery.
12.1.2 CPU Diagnostic LEDs
The BMC provides one amber LED per processor. The LEDs are turned on when a CPU has an
error.
Table 90. Processor Diagnostic LED Locations
LED Reference Designator Processor
DS5C1 1
DS5C2 2
DS5C3 3
DS5C4 4