Intel SE8500HW4 Server User Manual


 
Intel® Server Board Set SE8500HW4 Electrical Specifications
Revision 1.0
Intel order number D22893-001
59
Table 34. Typical Power-Up Timings
Ref Description Max Typical Min
t1 Time from front-panel power button push to BMC asserting the power button to the
chipset. This includes the private store update for Pwr State change, which is on the
order of 500ms + overhead, which accounts for other task completion time like Init
Agent. BMC also debounces signal for 50ms.
2s 1s 50ms
t2 Time from BMC asserting power button to chipset, until chipset responds with
SLP_S5.
– 16ms 60µs
t3 Time from when SLP_S5 is asserted, to when BMC asserts PS_ON_L to complete
system power-on.
1s 97ms 50ms
t4 Time from when BMC has completed driving its power-on signals, to when system
asserts power good back to BMC.
– 500ms 250ms
8.2.2 Power-Down Sequence
POWER_SW_L
(I)
SM_PWRBTN_L
(O)
SLP_S5P_L
(I)
PS_ON_L
(O)
SYS_PWROK
(I)
t1
t2
t4
t3
Figure 15. Typical Power-Down Sequence