Juniper Networks E-Series Network Router User Manual


 
CHAPTER 11
System Specifications
11-2
Airflow An integral air plenum directs router’s exhaust air below the router and out
the back. See Figure 3-2 in Chapter 3, Installation Guidelines and
Requirements.
DC Input
Voltage
Current
Power
Redundancy (input power)
–40 to –72 VDC
a
50 A @ –48 VDC
2400 W maximum
2 independent line feeds
NEBS Certification SR-3580 (FD-15): Network Equipment Building System (NEBS) Criteria
Levels, Issue 1, November 1995
GR-63 (LSSGR, FD-15): Network Equipment Building System (NEBS)
Requirements: Physical Protection, Issue 1, October 1995
GR-1089 (LSSGR, FD-15): Electromagnetic Compatibility and Electrical
Safety - Generic Criteria for Network Telecommunications Equipment, Issue
2, Revision 1, February 1999
Safety Agency Certification AS/NZS 3260:1993, Safety of Information Technology Equipment Including
Electrical Business Equipment
CAN/CSA C22.2, No. 60950-00, 3rd Edition, Safety of Information
Technology Equipment
EN60825-1, Safety of Laser Products - Part 1: Equipment Class,
Requirements, and User’s Guide (2001)
EN60950:2000, 3rd Edition, Safety of Information Technology Equipment
IEC 60950-1(2001-10) Ed. 1.0 Information technology equipment - Safety -
Part 1: General requirements
Low Voltage Directive (73/23/EEC)
UL 60950, 3rd Edition, Safety of Information Technology Equipment
Electromagnetic Emissions
Agency Certification
AS/NZS 3548:1995 (CISPR 22 Class A)
EMC Directive (89/336/EEC)
EN55022 Class A (CISPR-22 Class A)
EN55024, Annex C for WAN Equipment Performance Criteria A, B, and C
ETSI 300-386, Telecommunication Network Equipment; ElectroMagnetic
Compatibility (EMC) requirements
FCC Part 15 Class A
IECS-003 Issue 3 Class A
VCCI (Voluntary Control Council for Interference by Information Technology
Equipment)
Table 11-1 ERX-14xx models specifications (continued)
Category Specification