Juniper Networks E-Series Network Router User Manual


 
CHAPTER 12
Module Specifications
12-20
CT1
CT1
FULL
I/O
Non-ASIC ERX-7xx models
ERX-1410 router
SRP-5G
SRP-5G+
SRP-10G
24 RJ-48C
100 ohm
Use shielded cables to maintain
EMC compliance.
The line interface unit supports
multiple line build-outs.
Signal strength is software
controlled.
The transmitted signal complies
with ANSI T1.102-1993 Digital
Hierarchy - Electrical Interfaces
(1999) for cable lengths up to 201
m (660 feet).
CT3
CT3/T3
I/O
Non-ASIC ERX-7xx models
ERX-1410 router
SRP-5G
SRP-5G+
SRP-10G
3 BNC
75 ohm
The line interface unit supports
two line build-outs:
0–68.5 m (0–225 feet)
69–137 m (226–450 feet)
Signal strength is software
controlled.
The transmitted signal complies
with ANSI T1.102-1993 Digital
Hierarchy - Electrical Interfaces
(1999) for cable lengths up to 201
m (660 feet).
Table 12-3 I/O module specifications (continued)
I/O Module Label
a
Type
Model
Compatibility
SRP Module
Compatibility
No. of
Ports
Connector Type Cabling Specifications