Lenovo 6433 Server User Manual


 
2. Enter your product number (machine type and model number) or select Servers
from the Select your product list.
3. Select Servers from the Brand list.
4. From Family list, select ThinkServer TS100, and click Continue.
5. Click Downloads and drivers to download firmware updates.
6. From the BMC software, copy the files bmc.exe and Init.ini to a setup utility
diskette.
To start the mini-baseboard management controller setup utility program, complete
the following steps:
1. Turn on the server.
2. Insert the setup utility diskette into the diskette drive.
3. From a command line, type bmc and press Enter.
For the program to interface with the mini-baseboard management controller, the
parameters in the Intf.ini file must be set correctly. To modify the Intf.ini file, select 0
from the main menu and use the arrow keys to select settings for the following
parameters:
v System interface: This is the interface through which system software sends
and receives messages to and from the mini-baseboard management controller.
Select KCS (keyboard controller style).
v Port Address: This is the base address of the system interface.
v Register Spacing: Select ByteBoundary, ThirtyTwoBitBoundary,or
SixteenBitBoundary.
v Channel Number: Use the arrow keys to select the channel number (0 through
15).
v DHCP Mode: This is the LAN configuration address source.
Using the mini-baseboard management controller configuration
utility program
Use the mini-baseboard management controller configuration utility program to view
or change the mini-baseboard management controller configuration settings and to
save the configuration to a file for use on multiple servers.
To download the program, complete the following steps.
Note: Changes are made periodically to the Lenovo Web site. The actual
procedure might vary slightly from what is described in this document.
1. Go to: http://www.lenovo.com/support.
2. Enter your product number (machine type and model number) or select Servers
from the Select your product list.
3. Select Servers from the Brand list.
4. From Family list, select ThinkServer TS100, and click Continue.
5. Click Downloads and drivers to download firmware updates.
6. From the BMC software, copy the file bmc_cfg.exe to a configuration utility
diskette.
To start the mini-baseboard management controller configuration utility program,
complete the following steps:
1. Turn on the server.
2. Insert the configuration utility diskette into the diskette drive.
Chapter 2. Configuration information and instructions 27