Appendix A Specifications
© National Instruments Corporation A-9 DIO 6533 User Manual
Environment
Operating temperature ........................0 to 55° C
Storage temperature ............................–20 to 70° C
Relative humidity ...............................5% to 90% noncondensing
Functional shock.................................MIL-T-28800 E Class 3 (per
Section 4.5.5.4.1) Half-sine
shock pulse, 11 ms duration,
30 g peak, 30 shocks per face
Operational random vibration .............5 to 500 Hz, 0.31 grms, 3 axes
Nonoperational random vibration........5 to 500 Hz, 2.5 grms, 3 axes
Note: Random vibration profiles were developed in accordance with
MIL-T-28800E and MIL-STD-810E Method 514. Test levels exceed those
recommended in MIL-STD-810E for Category 1 (Basic Transportation,
Figures 514.4-1 through 514.4-3).