National Instruments DIO 6533 Switch User Manual


 
Chapter 5 Signal Timing
© National Instruments Corporation 5-17 DIO 6533 User Manual
Figure 5-14. Leading-Edge Mode Input Timing
Parameter Description Minimum Maximum
Input Parameters
t
rr*
REQ pulse width
75
t
r*r
REQ inactive duration
75
t
ar
ACK to next REQ
0—
t
dir(1)
Input data setup to REQ active
(with REQ-edge latching)
0—
t
rdi
Input data hold from REQ active
(with REQ-edge latching)
10
t
dir(2)
Input data setup to REQ
(with REQ-edge latching disabled)
0—
t
adi
Input data hold from ACK
(with REQ-edge latching disabled)
0—
Output Parameters
t
aa*
ACK pulse width
125
t
r*a*
REQ inactive to ACK inactive
150
All timing values are in nanoseconds.
REQ
ACK
Input Data
(REQ-edge
latching disabled)
t
r*r
t
r*a*
t
dir(2)
t
adi
t
ar
t
aa*
t
rr*
Input Data
(REQ-edge latching)
t
rdi
t
dir(1)