Chapter 5 Signal Timing
DIO 6533 User Manual 5-20 © National Instruments Corporation
Figure 5-17. Long-Pulse Mode Output
Long-Pulse Mode Timing Specifications
Figures5-18 and5-19 show the timing diagrams for long-pulse mode.
Wait
For
Data
Wait
For
REQ
Programmable
Delay
Programmable
Delay
Wait
For
REQ
When REQ
Asserted
When 6533 Device
Has Data to Output,
Output Data*
Clear
ACK
Pulse
When REQ
Unasserted
Initial State
ACK Cleared
Send
ACK Pulse
* With REQ-edge latching enabled, the data written is
delayed until the next inactive-going REQ edge.